Removal for the THERMAL FUSE ASSEMBLY
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LOWER HOUSING ASSEMBLY.
3 Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTOR next to the LOWER LIGHT BAFFLE ASSEMBLY.
4 Lift the MAIN BOARD up.
5 Cut and remove the necessary WIRE TIES.
6 Remove the brown wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH.
7 Remove the brown wire from the INTERLOCK SWITCH on the LOWER LIGHT BAFFLE.
8 Loosen the Torx SCREW on the PREHEAT DUCT approximately half way.
A091_4015BA
A091_4015BCA
MECHANISM BELT
FAN BELT