EasyManua.ls Logo

Kodak Ektalite 500 - Removal for the CYCLE SOLENOID ASSEMBLY

Kodak Ektalite 500
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL Removals and Installations
23JUL01
SM5766-1
Page
19 of 96
Removal for the CYCLE SOLENOID ASSEMBLY
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removals for the LOWER
HOUSING ASSEMBLY and the
MOTOR.
3 Disconnect the 3 CONNECTORS on
the MAIN BOARD. It is not necessary to
disconnect the CONNECTORS next to
the LOWER LIGHT BAFFLE
ASSEMBLY.
4 Lift the MAIN BOARD up.
5 Cut and remove the necessary WIRE
TIES.
6 Disconnect the 2 violet wires from the
CYCLE SOLENOID on the SMALL
BOARD.
7 Pull the SMALL BOARD up.
8 Remove the To rx SCREW from the
WORM PULLEY SHAFT.
9 Move the TAB on the WORM PULLEY
ASSEMBLY out of the MECHANISM
ASSEMBLY.
10 Lift and remove the WORM PULLEY
ASSEMBLY.
A091_4014GA
PLUNGER
SOLENOID
CYCLE
SOLENOID
CYCLE
A091_4014GCA
SCREW (2)

Table of Contents