SERVICE MANUAL Removals and Installations
23JUL01
SM5766-1
Page
38 of 96
Installation for the FOCUS SHAFT ASSEMBLY - 1500 and
2000 PROJECTORS Only
Important
Do the adjustments for the PHOTOCELL NULL and AUTO-FOCUS CLAMP after installation.
See the Adjustments section.
Removal for the FOCUS SHAFT ASSEMBLY - 500 and
1000 PROJECTORS Only
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LOWER HOUSING ASSEMBLY.
3 Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTOR next to the LOWER LIGHT BAFFLE ASSEMBLY.
4 Lift the MAIN BOARD up.
5 Remove the FOCUS KNOB.
6 Remove the 3 SCREWS from the LENS MOUNT ASSEMBLY.
7 Lift and remove the LENS MOUNT ASSEMBLY.
8 Remove the FOCUS SHAFT SPRING from the LENS MOUNT BRACKET.
9 Remove the E-RING and SPACER from the FOCUS SHAFT ASSEMBLY.
10 Remove the SCREW from the LENS SUPPORT BRACKET.
11 Lift and remove the LENS SUPPORT BRACKET.
12 Remove the E-RING and SPACER from the FOCUS SHAFT ASSEMBLY.
13 Remove the SCREW from the FOCUS MOTOR BRACKET ASSEMBLY.
14 Remove the FOCUS MOTOR BRACKET ASSEMBLY.