SERVICE MANUAL Adjustments
23JUL01
SM5766-1
Page
40 of 96
Section 2: Adjustments
CYCLE SOLENOID
Warning
Dangerous Voltage
1 Connect the main power.
Important
The CYCLE SOLENOID must operate correctly to do this adjustment.
The MECHANISM ASSEMBLY does not have to be removed to do this adjustment.
2 Do the removal for the LOWER HOUSING ASSEMBLY.
3 Bend the CYCLE LEVER up or down. Use T-BAR TL-3003.
4 Rotate the projector up.
5 Press the FORWARD BUTTON to check for correct operation.
6 Press the REVERSE BUTTON to check for correct operation.
7 Do the steps above until the FORWARD and REVERSE functions operates correctly.