EasyManua.ls Logo

Kodak Ektalite 500 - Removal for the LENS MOUNT ASSEMBLY - 1500 and 2000 PROJECTORS Only

Kodak Ektalite 500
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL Removals and Installations
23JUL01
SM5766-1
Page
32 of 96
Removal for the LENS MOUNT ASSEMBLY - 1500 and
2000 PROJECTORS Only
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LOWER
HOUSING ASSEMBLY.
3 Disconnect the 3 CONNECTORS on
the MAIN BOARD. It is not necessary to
disconnect the CONNECTOR next to
the LOWER LIGHT BAFFLE
ASSEMBLY.
4 Lift the MAIN BOARD up.
5 Remove the FOCUS KNOB.
6 Remove the short, gray wire connected
to the AUTO-FOCUS DEFEAT
SWITCH.
Important
It is necessary to push the AUTO-FOCUS
BRACKET backward and forward to allow
access to the SCREWS on the LENS
MOUNT ASSEMBLY.
7 Remove the 3 SCREWS from the LENS
MOUNT ASSEMBLY.
8 Lift and remove the LENS MOUNT
ASSEMBLY.
A091_4024GA
A091_4024GCA
LENS
MOUNT
ASSEMBLY
SCREW (3)