EasyManua.ls Logo

Kodak Ektalite 500 - Null

Kodak Ektalite 500
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL Adjustments
23JUL01
SM5766-1
Page
49 of 96
NULL
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LOWER HOUSING ASSEMBLY.
Important
It is necessary to use a FAN COVER TOOL.
3 Install the FAN COVER TOOL over the FAN area and the LAMP MODULE.
4 Energize the projector.
5 Set the projector to the LO-LAMP position.
6 Install and hold the AUTO FOCUS TARGET SLIDE TL-3002 until it is fully seated in the
GATE MECHANISM.
7 Look through the PROJECTION LENS hole and observe the focus light path on the
AUTO-FOCUS TARGET SLIDE TL-3002. Check that the light image is correct. If not, do
the adjustment for the FOCUS LIGHT PATH.
8 Check that the TAB on the CLAMP PAD ASSEMBLY is in the NULL position. If the TAB
is not in the correct position, do the adjustment for the NULL.
9 Bend the PHOTOCELL BRACKET to move the NULL in the center; use T-BAR TL-3003.

Table of Contents