SERVICE MANUAL Removals and Installations
23JUL01
SM5766-1
Page
17 of 96
Removal for the LAMP MODULE RECEPTACLE
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LOWER HOUSING ASSEMBLY.
3 Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTORS next to the LOWER LIGHT BAFFLE ASSEMBLY.
4 Lift the MAIN BOARD up.
5 Cut and remove the necessary WIRE TIES.
6 Disconnect the blue wire from P102 and the white wire from P10 on the MAIN BOARD.
7 Remove the 2 Torx SCREWS on the left side of the LOWER LIGHT BAFFLE
ASSEMBLY.
8 Loosen the Torx SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY
approximately 1/2 way.
9 Lift and remove the LOWER LIGHT BAFFLE ASSEMBLY.
10 Lift the GRILL ASSEMBLY up.
11 Remove the 2 long Torx SCREWS from the BLOWER COVER ASSEMBLY.
12 Lift the BLOWER COVER ASSEMBLY up.
13 Lift and move the PREHEAT DUCT up.