25 MODE
1 ADJUSTMENT
*13 Transfer/separation output for recycled paper
These bits are used when "Recycle" is selected
for "Paper type/special size setting" in the key
operator mode.
When "User paper" is selected with these bits,
the transfer/separation output for the user paper
setting made in the 36 mode is applied. When
"No specification" is selected, output data by
destination and paper size (metric or inch series)
(Japan/metric: 64 g/m
2
recycled paper, Inch: 20
lb recycled paper, Inch area/inch: 20 lb recycled
paper, metric: 80g/m
2
recycled paper, Metric
area/metric: 80g/m
2
recycled paper, inch: 20 lb
recycled paper) is used.
When humid paper causes uneven image, select
“humid paper 1/2/3”.
*14 Fixing roller initial rotation
Fixing may be insufficient if the temperature of
the place where the machine is installed is low.
To prevent this, increase the warm-up time (fix-
ing roller initial rotation time) to allow the fixing
roller to be evenly warmed up. This bit specifies
the condition(s) under which initial rotation of the
fixing roller is required.
• Low temperature: Initial rotation of the fixing
roller is carried out only under the low temper-
ature condition.
• Low and normal temperatures: Initial rotation
of the fixing roller is carried out under low and
normal temperature conditions.
• Low, normal, and high temperatures: Initial
rotation of the fixing roller is carried out under
low, normal, and high temperature conditions.
*15 Fixing roller initial rotation time setting
This bit sets the maximum time of initial rotation
of the fixing roller.
7155/7165
7255/7272
*16 Message switching
Mode 7-7 7-6 7-5
No specification
000
64 g/m
2
standard paper
(Japan)
001
20 lb standard paper (USA)
010
80g/m
2
standard paper
(Europe)
011
Humid paper 1 (Japan)
100
Humid paper 2 (USA)
101
Humid paper 3 (Europe)
110
User paper
111
Mode 8-3 8-2
Low temperature
00
Low and normal temperature
01
Low, normal, and high tem-
peratures
10
No initial rotation
11
Mode 8-5 8-4
2 minutes (Japan)
00
3 minutes (Inch and Metric series)
01
4 minutes
10
10 minutes
11
Mode 8-5 8-4
80 seconds
(Japan, High temperature and
high humidity)
100 seconds
(Japan, Except for high tempera-
ture and high humidity)
180 seconds
(Inch and Metric series, High tem-
perature and high humidity)
150 seconds
(Inch and Metric series, Except for
high temperature and high humid-
ity)
00
2 minutes
01
3 minutes
10
4 minutes
11
Mode 9-3 9-2
Please insert key counter.
00
Please insert copy card.
01
Please insert coin.
10
Please insert key counter.
11
4
MODEL MANUAL REVISED EDITION DATE PAGE METHOD
SERVICE MANUAL Dec. 2003
7155/7165/7255/7272
1-17 REPLACEMENT
4