2K3/2L3
1-3-36
U099 Adjusting original size detection
Description
Checks the operation of the original size sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size sensor mal-
functions frequently due to incident light or the like.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Method: [Data1/Data2]
1. Place the original and close the original cover or DP. The detection sensor transmission data
is displayed.
Item No. Description
Display Description
Data1 Displaying original size sensor transmission data
B/W Level1 B/W LEVEL setting original size sensor threshold value
Setting original size judgment time
Data2 Displaying original size sensor transmission data
(when DP is installed)
Display Description
Original Area R Detected original width size (R)
Original Area G Detected original width size (G)
Original Area B Detected original width size (B)
Original Area Detected original width size
Size SW L Displays the original size sensor (OSS) ON/OFF