2KW/2KX
1-3-11
U002 Setting the factory default data
Description
Restores the machine conditions to the factory default settings.
Purpose
To move the mirror frame of the scanner to the position for transport (position in which the frame
can be fixed).
Method
1. Press the start key.
2. Select [Mode1(All)] using the cursor up/down keys.
3. Press the start key.
The mirror frame of the scanner returns to the position for transport.
4. Turn the main power switch off and on.
* : An error code is displayed in case of an initialization error.
When errors occurred, turn main power switch off then on, and execute initialization using
maintenance item U002.
Error codes
Item No. Description
Codes Description
0001 Controller error
0020 Engine error
0040 Scanner error