2DF
1-4-51
Maintenance
Description
item No.
U504 Initializing the scanner NIC
Description
Initializing the optional scanner NIC to its factory default.
Purpose
To return to a setup at the time of factory shipments.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data in the scanner NIC is initialized.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U505 Setting Data Base Assistant
Description
Sets whether or not the database linkage setting is enabled if an optional network scanner is installed.
Purpose
According to user request, changes the setting.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Display Description
ON Database linkage setting is enabled.
OFF Database linkage setting is disabled.
Initial setting: ON
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U540 Adjusting the auxiliary scanning magnification
Description
Changes the magnification ratio in the auxiliary scanning direction when an optional network scanner is used.
Purpose
When an optional network scanner is used, if stripes appear at regular intervals in the auxiliary scanning
direction, this mode allows fine adjustment of the magnification ratio to suppress the stripes.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the resolution. The selected item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display Description Setting range Initial setting
200dpi Auxiliary scanning magnification -50 to +50 0
at the time of resolution 200 dpi
300dpi Auxiliary scanning magnification -50 to +50 0
at the time of resolution 300 dpi
400dpi Auxiliary scanning magnification -50 to +50 0
at the time of resolution 400 dpi
600dpi Auxiliary scanning magnification -50 to +50 0
at the time of resolution 600 dpi
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.