2KN/2KP
1-5-81
9. Insert the CIS to the DP.
* Pass the flexible flat cable through between
the roller and the frame as shown in the fig-
ure.
Figure 1-5-168
10. Connect other end of the flexible flat cable
to the CIS SHD PWB.
Figure 1-5-169
11. Insert the flexible flat cable between CIS
SHD PWB and guide.
Figure 1-5-170
12. Refit CIS using two screws, adjusting to the
installed position of the graduation of the
retainer.
13. Connect the connector.
14. Refit the DP front cover and original switch-
back guide to DP.
Flexible flat cable
Flexible
flat cable
CIS SHD PWB
Flexible flat cable
Flexible flat cable
Guide
CIS SHD PWB