EasyManua.ls Logo

Kyocera TASKalfa 620 - Page 54

Kyocera TASKalfa 620
521 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2KN/2KP-1
1-3-16
U034
Adjustment: Leading edge registration adjustment
1. Press the interrupt key.
2. Press the start key to output a test pattern.
3. Change the setting value using the cursor up/down keys.
For output example 1, decrease the value. For output example 2, increase the value.
Figure 1-3-1
4. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
Adjustment: Center line adjustment
1. Press the interrupt key.
2. Press the start key to output a test pattern.
3. Change the setting value using the cursor up/down keys.
For output example 1, decrease the value. For output example 2, increase the value.
Figure 1-3-2
4. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
Completion
Press the stop/clear key at the screen for selecting an item.
The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Correct image Output
example 1
Output
example 2
Leading edge registration (20 ± 1.0 mm)
U034
U066
(P.1-3-26)
U071
(P.1-3-30)
Center line of printing (± 0.5 mm)
Correct image Output
example 1
Output
example 2
U034
U067
(P.1-3-27)
U072
(P.1-3-31)

Table of Contents

Other manuals for Kyocera TASKalfa 620

Related product manuals