99
Specify the priority1 value to override the default criteria (clock quality, clock
class, etc.) for best master clock selection. Lower values take precedence. The range
for both is from 0 to 255., The default is 255
Priority2:
Specify a priority2 value to be used as a tie-breaker between two devices that
are otherwise equally matched in the default criteria. For example, you can use priority2
value to give a specific switch priority over other identical switches. The range for both
is from 0 to 255. The default is 255.
Announce Interval:
Specify the time for sending announce messages. The range is 0 to 4 seconds.
The default is 1 (2 seconds).
Announce Interval Timeout:
specify the time for announcing timeout messages. The range is 2 to 10 seconds.
The default is 2 (4 seconds).
Sync Interval:
enter the time for sending synchronization messages. The range is -1 second to
1 second. The default is 1 second.
Delay Request Interval:
specify the time recommended to the member devices to send delay request
messages when the port is in the master state. The range is -1 second to 6 seconds.
The default is 1 (2 seconds).