64
Interval
How frequent the switch will ping the IP address of PD.
Retry Time
How many times of ping failure the switch will define the PD as dead or failure.
Failure Log
Failure times of the PD detection.
Failure Action
When the switch can not detect the PD, there are several failure action to be set
as followings:
Nothing: No action
Power Down: shutdown the power of the PoE port
Power On: keep the power on with the PoE port
Restart Forever: Restart the power of the PoE port always.
Restart Once: only restart the PoE power one time.
Reboot time
To set the reboot time of PD in order for the switch to check PD connection after
PD is completely boot up.
6.7.4 Scheduling
The Poe scheduling is to feed or shut down PoE power over a routine schedule in the
following table.