104
Enter edit mode
There are 3 roles in the ring of G.8032, owner, neighbour and none ,
remember 3 roles are very import things during the setting procedure:
The port 0 of owner switch must connect with the neighbour
switch.
After enabling the ring of G8032, the port0 of owner switch will
be blocked at first.
To be safe, we suggest to finish all the settings of G8032 before connecting
physically if the user is not familiar with the ring G8032 function.
The setting of owner switch
(Because we only have single ring, so we set the type as Major)