1217=Extern text too large
External text is too long for the external text
object or false.
(Unauthorized characters?)
Read the script and interface
protocol documentation!
1218=X3 Outputdriver
overloaded.
Outputs disabled
The output drivers for the X 3 outputs logs
too hot (overload, short-circuit)
Note: in order to protect IC, all outputs are
switched off automatically.
Power in X 3 output driver too high. The
outputs were locked for safety.
Rebooting the system will activate
the outputs again.
Check if there is a short circuit
onto X3 input.
1219=Power input
overloaded.
Please check your power
supply net immediately
The input voltage is too high.
Check the power supply net for
over voltage.
1220=Object counter
reached end value. Print
has stopped.
An object counter has reached its defined
end.
See 0perating manual JET3up
Figure 8.7.3 Counter / Page218
ReleaseR1.06
1221=Job list reached end.
Print has stopped.
A job list (batch or job organisator) has
reached the end and will not be repeated.
See operating manual JET3up
Figure / Page ReleaseR1.06
1222=Job not loaded or
faulty
Job was not loaded or is corrupt.
Check the job settings in job
editor and save it again.
If jobs has been imported by USB
device, check if files are not
corrupt.
1223=Last Database record
printed.
Print has stopped.
Last database entry printed. Printing has
been stopped.
The database has reached the
end and printer stopped to print.