42
Service Manual JET3
1308
1308=Pressure fault.
Hydraulic control has
stopped. Please check air
pump and all connections.
The compressor could not build up the
pressure within 120 seconds (!)
1 Pneumatic part leaking
2. Defective compressor
(possibly even wiring!)
3. Air filter clogged"
1309
1309=Ink Flow sensor error.
Hydraulic control has
stopped.
Ink flow sensor reports out of ink
Possible causes:
1 Inkjet does not apply in the gutter tube
2. Even no ink-jet available
(Nozzle blocked, ink valve is not working)
3. Cable break or ink flow sensor contact
problem
4. Return flow sensor or wiring "flooded" with
ink.
Adjust ink stream
Clean nozzle
1310
1310=Ink tank reached low
level position. Please refill
ink.
Please refill ink.
1311
1311=Solvent tank reached
low level position. Please
refill solvent.
Please refill solvent.