1312=Leakage found in the
hydraulic area. Hydraulic
control has stopped. Please
check hydraulic
immediately.
Leakage sensor is giving alarm!
1 Hydraulic leakage
2. Any water on the bottom"
Check the hydraulic part if there is
any ink or solvent leak. If no leak
could be detected, clean leak
sensor with solvent and activate
hydraulic control again. If humidity
is found onto the leak sensor, dry
it and activate the hydraulic
control again.
1313=Invalid Hydraulic
Settings
Invalid hydraulic setting
(Pressure much too high, visco correction
factor much to low or much too big.)
1315=Inktyp not supported
Ink type is not supported in the printer.
Carry out a software update
If software update is without
success, please contact
LEIBINGER
5000=Charge Electrode
dirty.
Please check if charge
electrode is dirty and clean if
necessary.
"Causes:"
1. Electrode block dirty with ink
2. Head Electronics "filled with ink or solvent
", system leak
3. HV discharge onto head electronics
4. Error when reassembling deflection unit
head chassis (HV Cable crushed, seal