EasyManua.ls Logo

Leibinger JET3 up - Page 45

Leibinger JET3 up
214 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
5004
5004=Phasing error.
The time interval between
two PrintGo`s is too small.
Phasingerror.
The time interval between two PrintGo`s is
too small.
Increase delay or reduce production speed.
5010-5014
5010=An error occurred
while the function Nozzle
Open / Nozzle Close was in
process. Check the
mechanics for gutter-
movement.
No Encoder signals when attempting to drive
the motor.
Causes:
1. Motor is jammed
2. Encoder or encoder wiring defective
3. Motor or a faulty motor driver (motor does
not run)
4. Plug of the motor lose or filled with ink.
Clean the print head with solvent.
Change the nozzle motor.
Change controller board.
See the service document cleaning
print head of JET3up.
See the service document
Exchange controller board.
5015
5015=Motor direction
incorrect
Motor direction is wrong, i.e. the counting
direction of the encoder does not match the
desired direction of movement.
Change the nozzle motor.
Check if the connector of nozzle
motor is loose.
5016
5016=Nozzle was open
already during Power On
process.
Nozzle was open during the power-on
process.
It is only an info message to
remind you that the printer has
been switched off with an open
nozzle. Possible that mains went
off or mains plug has been
removed while the nozzle has
been open.

Table of Contents

Other manuals for Leibinger JET3 up

Related product manuals