Service Manual JET3
Rev. 1.0 67
12. Due to some special ingredients of the cleaner, the nozzle must be washed up with
tap water at the end of the cleaning process.
Blow out the nozzle with clean air pressure (2 - 6 bar). Center the air-gun exactly in
the
middle of the nozzle and blow out for several seconds. First against the nozzle
outlet and
then against the nozzle entry. This process can be repeated for an
unlimited number of
times.
13. To avoid that any remains of the special cleaner or water are still remaining on the
nozzle,
wash up the nozzle once more with solvent and dry it with air pressure.
14. Insert the nozzle and turn forward the knurled-head-screw to the end position.
Thereby the
cross bolt rotates 90 °and arrests the nozzle. Afterwards turn back the
knurled-head
screw about one rotation.