EasyManua.ls Logo

Leica mojo 3D - Setting the Overlap Limit

Leica mojo 3D
378 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Leica mojo3D, Automatic Section Control 153
7.2 Setting the Overlap Limit
Definition The overlap limit sets how sensitive the auto section control is to misses and over-
laps. When the overlap limit is set to its default value of 100%, the section will turn
on whenever any part of the sensed area has not been applied.
If the overlap limit is decreased, the system will not turn on the application when
traversing a small missed area, such as a strip between two spray swaths.
100% 50% 25% 0%