Step 2. Repeat the previous step on the second controller if you are in an HA configuration.
Note: Both controllers must be in Maintenance mode to run the interconnect test.
Step 3. At the LOADER prompt, access the special drivers specifically designed for system-level
diagnostics to function properly: boot_diags
During the boot process, you can safely respond y to the prompts until the Maintenance mode
prompt (*>) appears.
Step 4. Enable the interconnect diagnostics tests from the Maintenance mode prompt: sldiag device
modify -dev interconnect -sel enable
The interconnect tests are disabled by default and must be enabled to run separately.
Step 5. Run the interconnect diagnostics test from the Maintenance mode prompt: sldiag device run -dev
interconnect
You only need to run the interconnect test from one controller.
Step 6. Verify that no hardware problems resulted from the replacement of the chassis: sldiag device
status -dev interconnect -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status
of failures resulting from testing the component.
Step 7. Proceed based on the result of the preceding step.
84
ThinkSystem DM3000x and DM5000x Hardware Installation and Maintenance Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo ThinkSystem DM5000 series and is the answer not in the manual?

Lenovo ThinkSystem DM5000 series Specifications

General IconGeneral
BrandLenovo
ModelThinkSystem DM5000 series
CategoryStorage
LanguageEnglish

Related product manuals