Install a simple-swap drive
Use this information to install a simple-swap drive.
“Read the  
installation 
Guidelines” on 
page 45
“Power off  
the server  
for this task” 
on page 14
“ATTENTION:  
Static Sensitive Device  
Ground package before opening” 
on page 48
Notes: 
•  For a list of supported drives, see https://static.lenovo.com/us/en/serverproven/index.shtml.
•  The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the 
installation order when you install a drive. See “Front view” on page 17.
•  You can mix drives of different types and different capacities in one system, but not in one RAID array. 
The following order is recommended when installing the drives: 
–  Drive type priority: SATA SSD, SATA HDD
–  Drive capacity priority: the lowest capacity first
•  The drives in a single RAID array must be the same type, same size, and same capacity. 
Before installing a simple-swap drive: 
1.  If there is a drive filler installed, remove it and keep it in a safe place. 
2.  Touch the static-protective package that contains the new drive to any unpainted surface on the outside 
of the server. Then, take the new drive out of the package and place it on a static-protective surface. 
To install a simple-swap drive, complete the following steps: 
Figure 55. Simple-swap drive installation
Chapter 3. Hardware replacement procedures 83