Lenovo ThinkSystem SR530 - Install a Riser Card

Lenovo ThinkSystem SR530
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install a riser card
Use this information to install a riser card.
Read the
installation
Guidelines” on
page 45
Power off
the server
for this task”
on page 14
ATTENTION:
Static Sensitive Device
Ground package before opening”
on page 48
To install a riser card, complete the following steps:
Watch the procedure. A video of the installation process is available:
YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-AQrHuDWK6L3KtHWc6maY_O
Youku: http://list.youku.com/albumlist/show/id_50437162
Note: The riser assembly you want to install might be different from the illustrations below, but the
installation method is the same.
Step 1. Touch the static-protective package that contains the new riser card to any unpainted surface on
the outside of the server. Then, take the new riser card out of the package and place it on a static-
protective surface.
Step 2. Note the notch
1 on the riser card and ensure that the orientation of the riser card is correct as
shown. Then, align the screw holes in the new riser card with the corresponding ones in the bracket
and install the two screws to secure the riser card to the bracket.
Figure 78. Riser card installation
Step 3. Install a PCIe adapter on the riser card. See “Install a PCIe adapter” on page 109.
Step 4. Connect cables to the PCIe adapter on the riser card. See “Internal cable routing” on page 32.
112
ThinkSystem SR530 Maintenance Manual