•  The term “hot-swap drive” refers to all the supported types of hot-swap hard disk drives, hot-swap solid- 
state drives, and hot-swap NVMe drives.
•  Use any documentation that comes with the drive and follow those instructions in addition to the 
instructions in this topic. 
•  The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all drive 
bays covered or occupied. The vacant bays are either covered by an EMI-protective panel or occupied by 
drive fillers. When installing a drive, save the removed drive filler in case that you later remove the drive 
and need the drive filler to cover the place.
•  To avoid damage to the drive connectors, ensure that the top cover is in place and fully closed whenever 
you install or remove a drive.
Remove a 2.5/3.5-inch hot-swap drive
Use this information to remove a 2.5/3.5-inch hot-swap drive.
About this task
The following describes the information that you must consider for this task: 
•  Ensure that you have backed up data on your drive, especially if it is part of a RAID array. 
–  Before you make changes to drives, RAID adapters, or drive backplanes, back up all important data 
that is stored on the drives.
–  Before you remove any component of a RAID array, back up all RAID configuration information.
•  If one or more NVMe drives are to be removed, it is recommended to disable them first in Safely Remove 
Hardware and Eject Media (Windows) or filesystem (Linux). Log in to XClarity Controller and go to the 
Storage menu to identify and locate the drive type and corresponding drive bay number. If the drive bay 
numbers come with the term “NVMe”, it indicates the installed drives are NVMe drives.
Attention: 
•  Read “Installation guidelines” on page 83 to ensure that you work safely.
•  Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static- 
sensitive components in their static-protective packages until installation, and handling these devices with 
an electrostatic-discharge wrist strap or other grounding system.
•  To ensure that there is adequate system cooling, do not operate the server for more than two minutes 
without either a drive or a drive filler installed in each bay.
A video for this task is available at:  
•  YouTube: 
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Cmxb8e4L4PvMQ7J5PxvuOK
•  Youku: https://list.youku.com/albumlist/show/id_59643656
Procedure
Step 1.  If the security bezel is installed, remove it first. See “Remove the security bezel” on page 203.
Step 2.  Slide the release latch to the left to open the drive tray handle. 
Figure 64. Opening the drive tray handle
124 ThinkSystem SR630 V2 Maintenance Manual