After you finish
1. Complete the parts replacement. See “Complete the parts replacement” on page 224.
2. To enable the serial port module, do one of the following according to the installed operating system:
• For Linux operating system:
Open the ipmitool and enter the following command to disable the Serial over LAN (SOL) feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
• For Microsoft Windows operating system:
a. Open the ipmitool and enter the following command to disable the SOL feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
b. Open Windows PowerShell and enter the following command to disable the Emergency
Management Services (EMS) feature:
Bcdedit /ems no
c. Restart the server to ensure that the EMS setting takes effect.
System fan replacement
Use this information to remove and install a system fan.
Remove a system fan
Use this information to remove a system fan. You can remove a hot-swap fan without powering off the
server, which helps you avoid significant interruption to the operation of the system.
About this task
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
CAUTION:
Hazardous moving fan blades nearby. Keep fingers and other body parts away.
Attention:
• Read “Installation guidelines” on page 83 to ensure that you work safely.
Chapter 4. Hardware replacement procedures 209