Terminal data
X1 Specicaon Unit min. typ. max.
SIA, SIB LOW signal V -3 0 +5
HIGH signal V +15 +24 +30
Switch-on me ms 10
Clear me ms 15 30
Input current mA 8 12
Input peak current mA 400
Input capacitance SIA
µF 5
Input capacitance SIB
Test pulse dur
aon ms 1
Test pulse interval ms 10
GS Reference potenal for SIA and SIB
Runme = St
art of rising edge at SIA, SIB unl internal HIGH signal is detected.
Switch-o me = Start of falling edge at SIA, SIB unl internal LOW signal is
detected.
Connecon descripon Basic Safety - STO
Connecon X1
Connecon type Pluggable
Max. cable cross-secon mm² 1.5
Max. cable cross-secon AWG 16
Stripping length mm 9
Stripping length in 0.35
Required tool Screwdriver 0.4 x 2.5
Electrical ins
tallaon
Funconal safety
Basic Safety - STO