Ecodesign r
egulaon
Product informaon acc. to REGULATION (EU) 2019/1781 (ANNEX I, Secon 4)
Legend
Operang point (f; I) f = relave motor stator frequency; I = relave torque-producing current
Power losses Power losses at operang points (f; I) and in standby mode relate to the rated apparent output power.
For power losses for opons (e.g. for diagnoscs) and for accessories (e.g. mains chokes) please refer to further product
documentaon on the product web page.
Power losses
0; 25
f; I
% 2.9 2.5 1.6 1.1 1.0 1.2 0.8 4.2
0; 50
f; I
% 2.9 2.5 1.7 1.2 1.1 1.3 1.0 4.2
0; 100
f; I
% 3.1 2.7 2.0 1.5 1.5 1.7 1.5 4.5
50; 25
f; I
% 2.9 2.5 1.6 1.2 1.1 1.2 0.9 4.3
50; 50
f; I
% 3.0 2.6 1.8 1.3 1.3 1.4 1.1 4.3
50; 100
f; I
% 3.3 2.9 2.2 1.7 1.7 2.0 1.8 4.6
90; 50
f; I
% 3.1 2.7 1.9 1.4 1.4 1.5 1.2 4.4
90; 100
f; I
% 3.4 3.1 2.4 2.0 2.1 2.2 2.0 4.8
Standby losses % 1.5 1.3 0.9 0.5 0.3 0.2 0.2 1.3
Eciency level IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2
Manufacturer's name Lenze SE · Hans-Lenze-Str. 1 · 31855 Aerzen · GERMANY
Commercial registraon
number
Hannover HRB 204803
Product’s model idener I95AE137D I95AE155D I95AE175D I95AE215D I95AE222C I95AE240C I95AE255C I95AE155F
Apparent output power kVA 0.9 1.2 1.6 2.6 3.6 6.2 8.7 1.2
Indicave motor rated power
output
kW 0.37 0.55 0.75 1.5 2.2 4 5.5 0.55
Rated output current A 2.4 3.2 4.2 7 9.6 16.5 23 1.8
Maximum operang
temperature
°C 45
Rated supply frequency Hz 50
Rated supply voltage V 230 400
Switching frequency kHz 4
Rated apparent output power kVA 0.977 1.19 1.71 3.3 4.44 7.38 9.95 1.19
Technical data
E
codesign regulaon
180