Extended Safety
Extended safety is part of the product version i950AExxxF1C.
DANGER!
Loss of the safety funcon.
A loss of the sa
fety funcon causes an unsafe condion of the machine. The machine
condion cannot be controlled via the safety funcon.
▶
Always install the cables S1 and S2 in a protecve manner according to EN ISO 13849-2,
category 4.
The LEDs display the safety system status.
LED "RDY" (yellow) State Meaning
o - No status message acv
e
on
- Restart acknowledgement requested
Blinking 2 Hz
SOS acv
e
Blinking 1 Hz
Service status Parameter set transfer requested.
"ERR" LED (red) State Meaning
o - The device operates properly.
on
Crical de
vice error The device is defecve and must be replaced.
Blinking 2 Hz
Safety bus error No c
ommunicaon has been established via the safety
bus:
•
There is no valid conguraon
•
The acceleraon has not yet been completed
Blinking 1 Hz
Error in the safety system One of the following errors has been recognized:
•
Monit
oring device has been acvated
•
Discrepancy of the input
•
Errors to be acknowledged
Electrical ins
tallaon
Funconal safety
Extended Safety