Generate a c
onnecon between inverter and »EASY Starter«
For commissioning the inverter with the »EASY Starter«, a communicaon link with the
inverter is required. This can be established in a wired manner only.
How to establish a communicaon link via the X16 engineering port to the inverter:
Precondions
The inverter is ready for operaon (mains voltage is switched on).
No errors or faults.
Required accessories
Engineering PC with installed »EASY Starter«
Standard network cable
1.Insert the network cable into engineering port X16 of the inverter.
2.Use the network cable to connect the inverter to the PC on which »EASY Starter« is
installed.
3.Open the »EASY Starter« Start.
The "Add devices" dialog is shown.
4.Select the "Ethernet" connecon.
5.Press the Insert buon.
The »EASY Starter« searches the selected communicaon path for connected devices.
Following successful connecon, the inverter is shown in the device list.
The »EASY Starter« tabs then provide access to the inverter parameters.
Commissioning
Precondions
The mechanic
al and electrical installaon of the inverter is complete.
If necessary, the motor is mechanically decoupled from the system.
Check whether the system can be mechanically damaged if the non-decoupled drive
makes uncontrolled movements.
The inverter is supplied with voltage.
For parameterizaon purposes, it makes sense to supply the device with 24 V if the
mains voltage and the motor data deviate from the default seng.
If it has been ensured that the mains voltage and motor data sengs correspond to
the actual condions, the mains voltage can be connected.
The connecon between the inverter and the engineering PC with
installed »EASY Starter« has been established.
The »EASY Starter« is open and connected to the inverter.
The device list of the »EASY Starter« contains the inverter with the correct device
descripon.
For an explanaon of where the device list can be found, please consult the online help
of the »EASY Starter«. Press the F1 key to call up the online help.
No fault is indicated by the inverter diagnoscs.
Check the LED status displays. LED status display ^ 171
Check the error messages.
Check available applicaon credit on the storage medium.
Commissioning
Commissioning
Engineering t
ool »EASY Starter«
169

Table of Contents

Other manuals for Lenze I95AE222F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE222F and is the answer not in the manual?

Lenze I95AE222F Specifications

General IconGeneral
BrandLenze
ModelI95AE222F
CategoryInverter
LanguageEnglish

Related product manuals