EasyManua.ls Logo

Leuze BPS 307i - Page 13

Leuze BPS 307i
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device description
Leuze electronic GmbH + Co. KG BPS 307i 13
NOTICE
The configuration switches and the integrated parameter memory for simple replacement of the
BPS are located in the MK307.
1
2
1 1
1 3x cable bushing, M16x1.5
2 SERVICE: Mini-B USB socket (behind protective cap)
Fig.3.3: Connection hood MK307, connections
Cable fabrication and shielding connection
Ä Remove approx.78mm of the connection cable sheathing. 15mm of sheath of the shielded line must
be freely accessible.
Ä Lead the individual wires into the terminals according to the diagram.
NOTICE
Do not use wire-end sleeves!
Ä When fabricating cables, we recommend against using wire-end sleeves.
NOTICE
The shield is automatically contacted when the cable is lead into the metal screw fitting and fas-
tened when the cord grip is closed.
≈ 55 mm ≈ 8 mm ≈ 15 mm
1 2
1 Diameter of contact area, cable: 6…9.5mm
2 Diameter of contact area, shield: 5…9.5mm
Fig.3.4: Cable fabrication for connection hoods with spring-cage terminals

Table of Contents

Related product manuals