EasyManua.ls Logo

Leuze BPS 307i - BPS Without Heating

Leuze BPS 307i
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Leuze electronic GmbH + Co. KG BPS 307i 78
Tab.13.6: Certifications, conformity
Conformity CE, CDRH
Certifications UL60950-1, CSA C22.2 No.60950-1
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
13.1.1
BPS without heating
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
Tab.13.7: Electrical equipment
Data specification Values/description
Interface type SSI
SSI clock rate (CLOCK): 50kHz…800kHz
Service USB interface Mini-B type USB2.0 socket
PWR LED green Device ready (power on)
Operating voltage U
B
18…30VDC (Class 2, protection classIII)
Power consumption Max. 3.7W
Tab.13.8: Ambient temperature
Ambient temperature (operation) -5°C…+50°C
Ambient temperature (storage) -35°C…+70°C