Diagnosis and troubleshooting
Leuze electronic GmbH + Co. KG BPS 307i 72
Tab.10.5: Position measurement errors – causes and measures
Error Possible cause Measures
Measurement value or
reading quality is contin-
uously instable
Soiling of the BPS optics Clean the optics of the BPS
Measurement value or
reading quality is poor
at certain position
values
always at the same
position values
Soiling of the barcode tape Clean the barcode tape
Replace the barcode tape
No measurement value
can be determined
No code in scanning beam
Code not in the working range of the
BPS
Align the scanning beam with the
barcode tape
Align the BPS with the barcode tape
(working range 50mm…170mm)
Faulty measurement
value
Wrong barcode tape
BCB grid different from BPS configura-
tion
Preset or offset active.
Incorrect unit or resolution configured.
Change BPS configuration to the
barcode tape that is being used