RMON Alarms
RMON alarms provide a mechanism for setting thresholds and sampling intervals to generate
exception events on counters or any other SNMP object counter maintained by the agent. Both
the rising and falling thresholds must be configured in the alarm. After a rising threshold is
crossed, no rising events are generated until the companion falling threshold is crossed. After a
falling alarm is issued, the next alarm is issued when a rising threshold is crossed.
One or more alarms are bound to an event, which indicates the action to be taken when the alarm
occurs.
Alarm counters can be monitored by either absolute values or changes (delta) in the counter
values.
To enter RMON alarms:
1.
Click System Status > RMON > Alarms. All previously-defined alarms are displayed. The
fields are described in the Add RMON Alarm page below.
Counter ValueDisplays the value of the statistic during the last sampling period.
2.
Click Add.
3.
Enter the parameters.
Alarm Entry IndexDisplays the alarm entry number.
InterfaceSelect the type of interface for which RMON statistics are displayed.
Counter NameSelect the MIB variable that indicates the type of occurrence
measured.
Sample TypeSelect the sampling method to generate an alarm. The options are:
o
AbsoluteIf the threshold is crossed, an alarm is generated.
o
DeltaSubtracts the last sampled value from the current value. The
difference in the values is compared to the threshold. If the threshold was
crossed, an alarm is generated.
o
IntervalEnter the alarm interval time in seconds.
Rising EventSelect an event to be performed when a rising event is triggered.
Events are created in the Events page.
Rising ThresholdEnter the value that triggers the rising threshold alarm
Falling EventSelect an event to be performed when a falling event is triggered.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys LGS326P and is the answer not in the manual?

Linksys LGS326P Specifications

General IconGeneral
Switch typeManaged
Switch layer-
Quality of Service (QoS) supportYes
Combo SFP ports quantity2
Installed SFP+ modules quantity0
Gigabit Ethernet (copper) ports quantity26
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity24
10G supportNo
Number of VLANs128
Networking standardsIEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Virtual LAN featuresTagged VLAN
Copper ethernet cabling technology1000BASE-T, 100BASE-T, 10BASE-T
DHCP featuresDHCP client
Security algorithms802.1x RADIUS
Throughput38.69 Mpps
Jumbo frames9000
MAC address table8000 entries
Product colorBlack, Blue
LED indicatorsActivity, Link, PoE, System
Number of fans2 fan(s)
Memory typeDRAM
Internal memory128 MB
Input current3.5 A
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (typical)28.58 W
Total Power over Ethernet (PoE) budget192 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth200 mm
Width440 mm
Height44 mm
Weight3096 g