EasyManua.ls Logo

LiteOn EVO 6800 Series - Page 115

LiteOn EVO 6800 Series
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
115
Output
frequency
Bias
Up 2
command
Bias value is increased in steps as
defined in d4-02
Drive uses accel/decel times as
set in d4-02
Less
than 2s
Less
than 2s
More
than 2s
Figure 6.39 Up 2/Down 2 Bias when L4-010.0 Hz
L4-02 Frequency Command Acc./Dec Setting ( Up / Down 2)
Sets the acceleration/deceleration times to increase or decrease the frequency command bias
for Up/Down 2.
No.
Name
Setting
Range
Default
L4-02
Frequency Command Acc./Dec Setting ( Up2 / Down 2)
0, 1
0
0 : Current Acc./Dec. Time
The drive uses the currently active acceleration or deceleration time.
1 : Acc./Dec. Time 4
The drive uses the C1-06 (Acceleration Time 4) and C1-07 (Deceleration Time 4).
L4-03 Up/Down Frequency Command Save
No.
Name
Setting Range
Default
L4-03
Up/Down Frequency Command Save
0.00 to <1>
0.00 Hz
<1> The upper limit is determined by the values set to d1-02 (Maximum Output Frequency), d1-13 (Motor 2
Maximum Output Frequency) and L2-00 (Frequency Command Upper Limit).

Table of Contents

Other manuals for LiteOn EVO 6800 Series

Related product manuals