4.3.1.3 Control circuit input and output terminal (>7.5kW (more) models )
Table 4.3.1.3 Control Circuit Input Terminal
Terminal Type
Terminal
Code
Terminal Name
Terminal Description
Multi-Function
Digital Inputs
S1
Digital input terminal 1 (forward/stop)
Photocoupler, 24 V, 8 mA.
Use NPN/PNP switch to select
multi-function digital input type.
The default is NPN mode.
S2
Digital input terminal 2 (reverse/stop)
S3
Digital input terminal 3 (external fault 1)
S4
Digital input terminal 4 (fault reset)
S5
Digital input terminal 5 (multi-step
speed 1)
S6
Digital input terminal 6 (multi-step
speed 2)
S7
Digital input terminal 7 (Jog command)
In addition to the characteristic S1
~ S6, but also for the high-speed
pulse input channel.
Maximum input frequency: 50KHz