12. APPENDIX C: ERROR MESSAGES
Error messages may be displayed for a variety of reasons as detailed below.
12.1. BOUNCING LOAD
If the lift arms are bouncing significantly while weighing, an error occurs. This can happen if, for example, the loader is driven
over uneven ground while lifting the load.
Depending on the installation of the particular Loadrite Weighing System, there are two possibilities:
No weight is displayed and therefore there is no weight to add. Repeat the lift.
Weighing Error is turned off and a weight is displayed. Add the weight to the total (bearing in mind that the weight
measurement is not reliable) or ignore this weight and repeat the lift smoothly.
12.2. BUCKET BACK?
The bucket must be crowed fully back for each lift. The Bucket back? message will be displayed if the Loadrite Weighing
System has not detected that the bucket is fully crowded back.
NOTE: This message should only be displayed when using a Legal for Trade scale.
12.3. BUCKET NOT BACK
The bucket must be crowed fully back for each lift. The Bucket not back message will be displayed if the Loadrite Weighing
System has not detected that the bucket is fully crowded back.
NOTE: This message should only be displayed when using a Legal for Trade scale.
12.4. CHECK POWER
The power supply has reached an unstable level. Check that the power source is stable and between +12V and +32V.
12.5. CHECK MAG/OPT
There is a fault in the magnetic or optical trigger or the cable that connects the trigger. If using an optical trigger, check that the
lens is clear and dust-free.
12.6. CHECK ROTARY
There is a fault in the rotary trigger or the cable that connects the trigger. Check that the trigger is still securely mounted and that
the trigger finger has not been damaged.
12.7. CHECK SCALE#
This message displays when is pressed if the Indicator is set up for use with multiple scales.
If the weight is greater than 10% of full bucket capacity for the selected scale number, the screen displays Check Scale#
message. The operator needs to ensure the correct scale number is selected for the attached implement, as implements differ
considerably in weight.
12.8. CHECK TRANSDUCER
There is an error in the pressure transducer signal input. This indicates a fault in either the pressure transducer or the cable that
connects the transducer.