12.9. CHECK ZERO
The operator is automatically reminded to zero the bucket.
12.10. LIFT UNDER RANGE
The lift pressure was too low. This indicates a fault in either the pressure transducer or the cable that connects the transducer.
12.11. NEED EMPTYING
The bucket must be crowed fully forward to ensure that all product has been emptied. The Need Emptying message will be
displayed If the Loadrite Weighing System has not detected that the bucket has been crowded fully forward.
NOTE: This message should only be displayed when using a Legal for Trade scale.
12.12. NO LOCK
The interlock was not closed when lifting the load. The interlock must be closed (or the bucket must be fully rolled back) while
lifting the load. No weight is displayed and therefore there is no weight to add.
12.13. OVER TARGET
Adding the lifted weight will exceed the target value. The lifted weight can still be added by pressing .
NOTE: The Auto-add function will not automatically add over-target weight.
12.14. OVERLOAD
The lifted weight exceeds the full scale (capacity) setting. If the Overload Error is set during installation, overloaded weight
cannot be added.
12.15. POOR LIFT
If a weighing error is close to, but not greater than, the tolerance limit, the Loadrite Indicator displays this warning message. The
weight can be added as usual.
12.16. PRINTER DISABLED
Print function has been disabled at installation.
12.17. PRINTER ERROR
There is a fault in the printer. Check that the printer is online and has paper.
12.18. RETURN UNDER RANGE
The return pressure was too low. This indicates a fault in either the pressure transducer or the cable that connects the
transducer.