16A-1
STARTING - LOAD
Alternator: General information
K7J or K7M, and 710
16A
I -OPERATION
These vehicles are equipped with an internal ventilation
alternator with integrated regulator, and a warning light
on the instrument panel that works as follows:
- the warning light lights up when the ignition is swit-
ched on,
- the light goes out when the engine is switched off,
- if the indicator light comes on while the engine is run-
ning, it indicates a battery « charge » fault.
II - IDENTIFICATION
III - CHECKING
Alternator minimum guaranteed flows under 13.5 V af-
ter 15 minutes of heating with the engine running and
electrical consumers switched on.
Engine Alternator Current strength
K7J 710 DM
K7M 710 DM
MELCO: A001TA3792 70 A
K7J 710 PAS
K7M 710 PAS
VALEO: SG7 S013 75 A
K7J 710 MS/AC
K7M 710 MS/AC
MELCO: A002TC0391 110 A
K7J 710 PAS/AC
K7M 710 PAS/AC
BOSCH: 0124415014 100 A
Engine speed MELCO
70 A
VALEO
75 A
MELCO
110 A
BOSCH
100 A
rpm AAAA
1000 55 53 80 71
2000 72 73 108 96
3000 77 75 116 99
4000 79,5 79 120 100