Technical Manual LÖWEN Dart HB8
01/2019 72
7.2.1 t01 - SEL bUt: Push-Button Switch Test
Testing all front push-button switches.
1. Press [TEST] button on the controller board.
tSt appears in the TEM SCORE display.
2. Press [OPTIONS II] button to confirm.
SEL bUt appears in player 1 – 2 display and t01 in the TEMP SCORE display.
3. Press [OPTIONS II] button to start the test.
4. Press [GAMES] button.
9SL appears in the TEMP SCORE display.
5. Press [OPTIONS I] button.
OPI appears in the TEMP SCORE display.
6. Press [OPTIONS II] button.
OP2 appears in the TEMP SCORE display.
7. Press [PLAYER CHANGE] button.
PLC appears in the TEMP SCORE display.
8. Press [PROGRAM] button on the controller board.
Pr9 appears in the TEMP SCORE display
9. Press [TEST] button to exit the test.
7.2.2 t02 - SEL dIS: 7 Segment Display and LED Test
Testing 7 segment display and LEDs.
1. Press [TEST] button on the controller board.
tSt appears in TEMP SCORE display.
2. Press [OPTIONS II] button to confirm.
3. Press [GAMES] or [OPTIONS I] button until SEL dIS appears in player 1 – 2 display and t02 in the
TEMP SCORE display.
4. Press [OPTIONS II] button to start the test.
Every 7 segment display successively displays numbers 0 thru 9 and decimal point.
After all segments and LEDs have been tested, this program automatically returns to TEST mode tSt.