Technical Manual LÖWEN Dart HB8
01/2019 73
7.2.3 t03 - SEL SOU: Audio Test
This test will generate a continuous tone to check and adjust volume.
1. Press [TEST] button on the controller board.
tSt appears in the TEMP SCORE display.
2. Press [OPTIONS II] button to confirm.
3. Press [GAMES] or [OPTIONS I] until SEL SOU appears in player 1 – 2 display and t03 in the TEMP
SCORE display.
4. Press [OPTIONS II] button to start the test. You will hear a continuous tone.
5. Press [PLAYER CHANGE] button to exit the test.
NOTICE Volume control (SPEAKER VOLUME) is located in the lower left corner of the
controller board.
7.2.4 t04 - SEL tAr: Target Segment Test
This test checks if each target segment will register thrown darts correctly.
1. Press [TEST] button on the controller board.
tSt appears in the TEMP SCORE display.
2. Press [OPTIONS II] to confirm.
3. Press [GAMES] or [OPTIONS I] until SEL tAr appears in player 1 – 2 display and t04 in the TEMP
SCORE display.
4. Press [OPTIONS II] button to start the test.
5. Press each individual target segment. The corresponding score for each segment will be displayed in
the TEMP SCORE display. “Double" or "triple" will be displayed with "d" or "t" plus segment value (for
example, “double 20” will be displayed as “d20").
6. Press [PLAYER CHANGE] button to exit the test.