Page 14 INSTALLATION & USER'S MANUAL SL2
DISPLAY SYMBOLS AND MESSAGES
Symbol for switched off white light.
Symbol for switched on white light.
Symbol for any electro-mechanic error. Might be referred as an over voltage or
over current for motor drivers. Communication error with motor drivers will result in
the same symbol. This error symbol can be reset by simply enter the main menu
and select status. Then press “dismiss”. If over current have occurred the problem
might be referred as a stucked lamp housing check for any icing issues. Each
axis has its own symbol showing in upper left or right corner of the display.
This symbol and a similar symbol indicate the direction of the lamp housing both
for the vertical axis and for the horizontal axis. The arrows in the shown symbol
indicate the elevation angle for the vertical axis according to the horizontal-plane.
For the horizontal symbol and axis these small arrows indicate if the housing is
directed to the left, front, right or back of the centerline.
If the arrows are replaced by questionmarks then the system needs to be internally
calibrated. The easiest way to do the internal calibration is by simply choose the
Park” in the quick start menu, please see 15.6 Off and park.