Page 54 INSTALLATION & USER'S MANUAL SL2
Status
This menu will give information in form of text messages if there is errors.in the system, it also
contains a “Lamp-hour counter” showing the accumulated total running time in hours for each
LED-module.
Errors can be reset from this menu by simply press the button marked “Dismiss”, if errors
persist despite resetting, contact Luminell.
The errors presented below will also trigger the alarm output relay and give an audible and/or
visual alarm if connected to the vessels alarm monitoring system.
Status Message
Error
Remedy
Communication
error
Transmission issues on the CAN bus
Check for loose CAN-wires in
the electrical box or junction
points (if any) and contact
Luminell.
Over current
Overcurrent protection triggered;
movement blocked
Check that the searchlight is
able to rotate freely.
In winter, heavy icing can be the
cause of this error.
Over voltage
Overvoltage protection triggered, voltage
to searchlight motordriver/s have
exceeded 40Vdc.
Reset the error, if error recurs
repeatedly, please contact
Luminell.
Under voltage
Undervoltage protection triggered, voltage
to searchlight motordriver/s has fallen
below 8,5Vdc
Reset the error, if error recurs
repeatedly, please contact
Luminell.
OPWDT
(message in
box only)
Ethernet communication broken to all
panels, see (4.1) OP WDT.
Fault auto-resets if contact is restored with
at least one panel.
Check Ethernet wires and
connections to panel(s) and
switch.