INSTALLATION & USER'S MANUAL SL2 Page 57
Maximum rotation speed
This menu gives the operator the opportunity to limit the actual maximum rotation speed of the
searchlight in relation to its absolute maximum rotation speed.
The adjustment is done by moving the joystick forward to change speed in increments of 5%
and backwards to decrease. Minimum speed is 20% and maximum 100%, when the choice is
confirmed with "OK", the display jump back to the previous "Settings" - menu.
Installation
In this menu there are six sub menus each described below:
Store origin
This menu is used to calibrate the systems “ZERO” point for both vertical and horizontal axis.
Before the “Store origin” command is stored it is necessary that the synchronization between
operator panel and electrical box is done properly. The easiest way to do the synchronization is
by turning the system off with the “Park” command, please see 15.6 Off and park.
Start the system according to 12. STARTING SYSTEM (normal start). Now the position of the
lamp housings should be adjusted to be in level with horizontal plane and in direction straight
forward of the vessel (normally)! Then “Store origin” is executed and setting is stored.