INSTALLATION & USER'S MANUAL SL2 Page 45
After pressing “Store” a new menu will appear, “Pause Length. This defines how long the
searchlight will rest at this position before starting to move to the next position. Pause length
can be set between zero and ten seconds.
Repeat this for the desired number of positions.
When done go back to the “Surveillance” submenu by pressing Back”.
Navigate to “Start” and press “OK” to start the surveillance sweep.
The surveillance sweep will start from position one and go to position two and so until the
searchlight has come to the number set in “Number of Positions to Use
Changing surveillance settings
Surveillance has a couple of different settings, “Loop ModeandSpeed”.
In “Loop Mode there are two choices, “Back and Forth” and “Repeat”.
To set “Back and Forth” or “Repeat” enter the “Surveillance” submenu then “Loop Mode”.
When using “Back and Forth” the surveillance sweep will go from position one to two and so on
until it reaches the last one set in “Number of Positions to Use”. Then it will start calling these
positions in reverse order!
When using “Repeatthe surveillance sweep will go from position one to two and so on until it
reaches the last one set in “Number of Positions to Use”.
From there it will start the same sequence at position one instead of going to the previous
position.