6.2 Program Serial Number (TX & RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter Serial Number setting.
3) Press “” and “” button to change serial number as a whole or…
4) Press “” button to go to the 1
st
digit on the far left of the serial number.
5) Press “” and “” button to change numeric value.
6) Press “” button to go to the next digit to the right and repeat step 5.
7) Press “BACK” button to go back to step 3 or 4.
8) Exit Program Serial Number by pressing the “BACK” button until the cursor
is shown next to “S/N”.
9) Press “” and “” button to scroll through other Flex 2JX settings.
When finished, make sure to transfer the newly selected serial number to the receiver.
6.3 Program System Type (TX & RX)
System Type is associated with functions such as tandem operation,
random access operation, multi-receiver operation, etc... Please do not
alter the factory settings unless authorized to do so.
6.4 Program System Frequency Range (TX & RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter System Frequency Range setting.
3) Press “” and “” button to change frequency range.
4) Exit Program System Frequency Range by pressing the “BACK” button
until the cursor is shown next to “FREQ:”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
When changing the frequency range table in I-Chip make sure the transmitting and receiving
RF boards are also changed accordingly.
6.5 Program System Channel (TX & RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter System Channel setting.
3) Press “” and “” button to change system channel as a whole or…
4) Press “” button to go to the digit on the left.
5) Press “” and “” button to change numeric value.
6) Press “” button to go to the next digit to the right and repeat step 5
7) Press “BACK” button to go back to step 3 or 4.
8) Exit Program System Channel by pressing the “BACK” button until the
cursor is shown next to “CHANNEL”.
9) Press “” and “” button to scroll through other Flex 2JX settings.
When transmitter channel is changed make sure the receiver channel is also set to the
newly selected channel.