6.16 Program SW1 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW1 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW1 Function by pressing the “BACK” button until the cursor is
shown next to “SW1FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A→B” or “0→A→B” or “A→B→AB” or “0→A→B→AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A→B→C” or “0→A→B→C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A→AB→B” for Select A/A+B/B output relay contacts. Select “A→B→C” or
“0→A→B→C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW1 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.17 Program SW2 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW2 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW2 Function by pressing the “BACK” button until the cursor is
shown next to “SW2FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A→B” or “0→A→B” or “A→B→AB” or “0→A→B→AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A→B→C” or “0→A→B→C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A→AB→B” for Select A/A+B/B output relay contacts. Select “A→B→C” or
“0→A→B→C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW2 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.18 Program SW3 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW3 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW3 Function by pressing the “BACK” button until the cursor is
shown next to “SW3FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Rotary Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A→AB→B” for Select A/A+B/B output relay contacts. Select “A→B→C” or
“0→A→B→C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW3 is set to one of the above settings then the SW3 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).