6.16 Program SW1 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW1 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW1 Function by pressing the “BACK” button until the cursor is
shown next to “SW1FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “AB” or “0AB” or “ABAB” or “0ABAB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “ABC” or “0ABC”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW AABB” for Select A/A+B/B output relay contacts. Select “ABC” or
“0ABC” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW1 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.17 Program SW2 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW2 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW2 Function by pressing the “BACK” button until the cursor is
shown next to “SW2FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “AB” or “0AB” or “ABAB” or “0ABAB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “ABC” or “0ABC”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW AABB” for Select A/A+B/B output relay contacts. Select “ABC” or
“0ABC” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW2 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.18 Program SW3 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW3 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW3 Function by pressing the “BACK” button until the cursor is
shown next to “SW3FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Rotary Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW AABB” for Select A/A+B/B output relay contacts. Select “ABC” or
“0ABC” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW3 is set to one of the above settings then the SW3 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).