Page 54
9.11 Program Channel Scanning Function (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter Channel Scanning setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program Channel Scanning Function by pressing the “BACK” button until
the cursor is shown next to “CH SCAN”.
5) Press “↑” and “↓” button to scroll through other Flex EP-H settings.
Select “01” the receiver only scans the channel set on the receiver.
Select “02” the receiver scans the channel set on the receiver plus the next channel up (scans
channel N and channel N+1).
Select “03” the receiver scans the channel set on the receiver plus the next two channels
up (scans channel N, channel N+1 and channel N+2).
Select “ALL” the receiver scans all 62 channels.
9.12 Program MAIN Relay Function (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter MAIN Relay setting.
3) Press “↑” and “↓” button to scroll and select between Test and Normal.
4) Exit Program MAIN Relay Function by pressing the “BACK” button until
the cursor is shown next to “MAIN RLY”.
5) Press “↑” and “↓” button to scroll through other Flex EP-H settings.
Select “NORMAL” for normal operation (receiver mains and all other outputs enabled).
Select “TEST” for system testing (receiver mains disabled and all other outputs enabled).
9.13 Program Function Relay 1 / K21 Relay (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter Function Relay 1 setting.
3) Press “↑” and “↓” button to scroll and select.
4) Exit Program Function Relay 1 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY1”.
5) Press “↑” and “↓” button to scroll through other Flex EP-H settings.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT : FUNCTION relay works simultaneously with the receiver MAIN relays.
S/P : FUNCTION relay closes when Start command is initiated and opens only when
transmitter power is turned off.
HORN : FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
G SENSOR : FUNCTION relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.