Page 69
9.31 Program PB1 Outputs (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter PB1 Output setting.
3) Press “” button again then “” and “” button to scroll and select “Digital”,
“Current”, Voltage or “PWM”.
4) Press “BACK” button and then “” and “” button to select values for “Current”,
“Voltage”, and “PWM” settings.
5) Press “” button to enter setting and “” and “” button to select numeric
value for the digit to the far left. Press “” button to go to the next digit and
press ” and “” button to select.
6) Press “BACK” button to go back to step 5.
7) Exit Program PB1 Output by pressing the “BACK” button until the cursor is
shown next to “PB1 OUT”.
8) Press “” and “” button to scroll through other Flex EP-H settings.
8.32 Program PB2 Outputs (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter PB2 Output setting.
3) Press “” button again then “” and “” button to scroll and select “Digital”,
“Current”, Voltage or “PWM”.
4) Press “BACK” button and then “” and “” button to select values for “Current”,
“Voltage”, and “PWM” settings.
5) Press “” button to enter setting and “” and “” button to select numeric
value for the digit to the far left. Press “” button to go to the next digit and
press ” and “” button to select.
6) Press “BACK” button to go back to step 5.
7) Exit Program PB2 Output by pressing the “BACK” button until the cursor is
shown next to “PB2 OUT”.
8) Press “” and “” button to scroll through other Flex EP-H settings.
8.33 Program PB3 Outputs (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter PB3 Output setting.
3) Press “” button again then “” and “” button to scroll and select “Digital”,
“Current”, Voltage or “PWM”.
4) Press “BACK” button and then “” and “” button to select values for “Current”,
“Voltage”, and “PWM” settings.
5) Press “” button to enter setting and “” and “” button to select numeric
value for the digit to the far left. Press “” button to go to the next digit and
press ” and “” button to select.
6) Press “BACK” button to go back to step 5.
7) Exit Program PB3 Output by pressing the “BACK” button until the cursor is
shown next to “PB3 OUT”.
8) Press “” and “” button to scroll through other Flex EP-H settings.